MachineCalcs

Pump Head Loss Calculator for Plumbing

Pump head loss in a plumbing run is the pipe pressure drop converted into equivalent fluid head. Use it before selecting a pump curve or checking NPSH.

pump head loss calculator plumbing pipe head loss calculator plumbing pump head loss calculator

Head from pressure drop

head_loss = dp / (rho * g)

Friction plus fittings

dp = (f * L / D + sumK) * rho * v^2 / 2

Pump-selection caution

Head loss is only the system-piping portion. Elevation, valves, strainers, heat exchangers, control points and pump curves still govern final selection.